A vacuum deaerator lowers pressure around a liquid so gas can leave the product. It can reduce entrained air and some dissolved gas, but its result depends on temperature, product exposure and stable flow through the vessel.
If juice still foams at the filler, first establish whether the air remains after deaeration or enters again during transfer. Those are different faults with different remedies.
How continuous deaeration works
Product enters a vessel maintained below atmospheric pressure. An appropriate inlet arrangement exposes the liquid as a film, droplets or another configuration suitable for the design. Released gas leaves through the vacuum system while a discharge arrangement removes treated product.
Feed and discharge must remain balanced so the vessel operates at its intended product level. A stable vacuum reading with an unstable liquid level does not establish a stable process.
The [Tetra Pak deaeration chapter](https://dairyprocessinghandbook.tetrapak.com/chapter/deaerators) describes vacuum removal of dissolved and finely dispersed air. The arrangement and position in a line depend on the product and connected equipment.
Gauge vacuum and absolute pressure
Vacuum instruments may display a negative gauge value or a positive absolute-pressure value. Comparing the numbers without identifying the reference can cause an incorrect specification.
Absolute pressure = local atmospheric pressure + gauge pressure.
For illustration, if local atmospheric pressure is 101.3 kPa and the gauge reads −75 kPa, the absolute pressure is approximately 26.3 kPa. The same gauge reading at a different atmospheric pressure gives a different absolute pressure.
This conversion is a measurement example, not a recommended operating setting. Ask the supplier to state the pressure reference, measurement location and permitted operating range for the actual product.
Why temperature belongs in the specification
Gas release and boiling behaviour change with temperature and pressure. Increasing vacuum without considering product temperature can cause unwanted flashing, foam carryover or loss of volatile components.
Juice aroma and composition may place limits on the treatment. Define the acceptable product change and the handling of vapour or condensate before setting a trial. Vacuum deaeration should not be assumed to remove all oxygen or to establish shelf life by itself.
Locate where foam returns
Take comparable samples at the deaerator inlet, its discharge and the filler inlet. Where practical, record dissolved oxygen or an agreed air-content indicator as well as visible foam.
| Observation | Investigation to prioritize |
|---|---|
| Foam already high at the feed | Upstream mixing, falling streams and pump suction conditions |
| Unstable vessel level and vacuum | Feed-discharge balance, controls and possible leaks |
| Low visible air after treatment, foam at the filler | Transfer piping, receiving hopper and filling conditions |
| Product enters the vacuum line | Foaming behaviour, vessel loading and the specified carryover protection |
| Acceptable appearance but oxygen target missed | Measurement method, exposure conditions and the product-specific trial |
Visible foam is useful evidence, but it is not a direct measurement of dissolved oxygen. Use the agreed quality endpoint when judging the machine.
Size the whole vacuum system
Liquid throughput alone does not define the vacuum-pump load. Released gas, vapour, leakage and the selected operating conditions contribute to that load. Specify the product temperature, viscosity, initial air condition and target result together with the flow rate.
Also confirm discharge-pump suitability, cleaning access and the available utilities. A vessel, vacuum pump and product pump must work together at the proposed duty.
Should the deaerator always follow homogenization?
No single position fits every line. The location should remove air introduced by relevant upstream operations while remaining compatible with later heat treatment, transfer and hygiene requirements. Agree on the line sequence for the actual product.
Verify the pressure measurement before comparing settings
Two instruments can display different numbers while describing the same vessel pressure if one uses gauge pressure and the other absolute pressure. Unit differences can make the comparison harder, especially where one record uses MPa and another uses kPa or bar.
Record the instrument's reference, unit, measurement location and calibration status. Include local atmospheric pressure where it is needed for conversion. Keep the original reading alongside the converted value so the record remains traceable.
A negative number copied from another installation is not a complete process setting. The supplier needs the actual product temperature and the pressure definition to explain the proposed condition.
Distinguish a flow problem from an air-removal problem
Observe feed, product level and discharge together during a representative run. Mark when the vacuum changes, when the level moves outside its intended range and when the outlet flow changes.
If the vessel repeatedly fills and empties, samples collected at different moments may have received different exposure. An average throughput can conceal that variation. Stabilizing the connected feed and discharge arrangement may be necessary before assessing the deaeration result.
Conversely, stable level and flow do not prove that the required gas-removal endpoint has been reached. The quality measurement remains necessary. Separate the mechanical operating record from the product-result record and compare them over the same time interval.
Use comparable samples for oxygen or foam assessment
State how samples are collected and how quickly they are measured. Sample handling can introduce air or change foam condition, so inconsistent handling can create misleading differences between process locations.
Where dissolved oxygen is the acceptance measure, identify the instrument and measurement conditions. Where the requirement concerns visible foam, define a reproducible observation method rather than relying on an informal judgement that one sample looks better.
Record the untreated baseline at the same product condition. A result after treatment is easier to interpret when its starting point is known, particularly if upstream mixing or feed handling changes during the trial.
Follow the product after the vacuum vessel
The liquid-preparation process map helps show how mixing, heat treatment, deaeration and transfer fit together. Mark the deaerator's location and every later point where the product enters another vessel or pump.
At each receiving step, check whether the intended transfer keeps the product in a controlled flow or allows a substantial falling stream. The objective is to identify possible air entry from the actual layout, not to assume that a deaerator's outlet condition will automatically remain unchanged throughout the plant.
If the filler introduces the visible foam, an upstream vacuum change may offer little benefit. Compare the filler inlet sample with the filled package before deciding where additional equipment is needed.
Include vapour and condensate in the system review
The vacuum equipment handles what leaves the vessel, which can include gas and vapour under the selected conditions. Ask the supplier how the system deals with carryover and any collected liquid.
Define the required utilities and their operating conditions. If cooling water or another service varies during the shift, explain that variation before accepting a vacuum-system estimate. The duty should describe a sustained production condition rather than a pressure achieved only in an empty vessel.
Judge the installation with a complete trial record
For each evaluated condition, record product flow, inlet and outlet temperatures, vessel pressure, product level and the agreed quality result. Add interruptions, adjustments and material retained in the system.
Ask the supplier to distinguish the tested throughput from any proposed higher capacity. A good sample produced at one condition should remain evidence for that condition. A clear record makes it possible to improve air removal without treating every foam symptom as proof that a larger vacuum pump is required.
The [vacuum degasser page](/product/vacuum-degasser/) describes the current equipment range. For a trial proposal, [send juice type, flow, temperature, viscosity, pressure reference and the foam or oxygen target](/contact/). Include a simple process sketch showing the mixer, heat treatment, pumps and filler.